Product Code: PCE-830-2-ICA
Three Phase Power Data Logger incl. ISO Calibration Certificate PCE-830-2-ICA, 3-Phase Power Data Logger AC Current Clamp-on Meter Analyzer 3-Phase Power Data Logger AC Current Clamp-on Meter ISO Calibration Certificate: The PCE-830 Power Data Logger is used for measuring one to three phases of electrical quantities for alternating current (AC). This Power Data Logger also measures such parameters as voltage, current, frequency, harmonics and power as well as indicting, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values. - PCE-830 + PCE-6802 amp clamp (1000 A) - Electrical conductor pick-up: 55 mm diameter - Range selection: manual (10 A, 100 A, 1000 A) - Clamp dimensions: 244 x 97 x 46 mm - Incl. ISO calibration certificate Calibration certificates are issued specifically for the customer and are excluded from the right of return. Power Data Logger with 3 phases, measures power and analyses harmonics with memory, interface and sofware The PCE-830 3-phase-power meter is used for measuring one to three phases of electrical quantities for alternating current (AC). This 3-phase-power meter also measures such parameters as voltage, current, frequency, hrmonics and power as well as indicting, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values. The backlit LCD, with high resolution, can show up to 35 parameters simultaneously. It can have up to 3 clips attached at the same time. In data logger mode, it can save up to 17,470 readings (3 phases / 4 conductors), in a simpler set up (1 fase / 2 conductores) it can save up to 52,400 readings, split into 85 groups. All this makes the PCE-830 3-phase-power meter the ideal instrument for taking measurements over long durations. Measurement values obtained can be sent to a computer and be processed with the analysis siftware which comes included. The device comes with everything needed to being measuring and analysing from the moment the device arrives. Although the 3-phase-power meter comes calibrated from the manufacturer, an optional laboratory calibration and certificate, that meets ISO standards, can be ordered seperately with the device or when a recalibration is required. - Analysis of a network of 3 phases/4 conductors, 3 phases/3 conductors, 1 phase/2 conductors, 1 phase/3 conductors - Measures effective real value (V 123 and I 123) - Measures active power (W, KW, MW, GW) - Measures apparent and reactive power (KVA, KVAR) - Power Factor (PF), phase angle (Φ) - Measures energy and work (Wh, KWh, KVARh, PFh) - Measures current from 0.1mA to 3000A, allowing for the reserve power of a factory to be determined - Large LCD that shows up to 35 parameters simultaneously (3P4W [=3 phases/4 conductors]) - CT conditions (1 to 600) and PT (1 to 3000) are programmable - Indicates current wave forms and voltage overlap. - 512KB of memory with programmable intervals to save data every 2 to 3000 seconds, 17,470 readings using the system of 3 phases / 4 conductors) - Indicates wave forms, efficiency parameters and harmonic distortion - Backlit LCD wth dot matrix - Average power (AD in W, KW, MW) - Maximum power (MD in W, KW, MW) with the programmable period - Analysis of harmonic distortion up to a curvature of 99 - Indication of up to 50º form of harmonic wave - Indication of the wave form with maximum value (1024 readings / period) - Analysis of absolute distortion (%THD-F) - Diagram of graphic equilibrium with parameters of a 3 phase system - Detects up to 28 transistors (time and cycles) with a programmable threshold (%) - Relation of 3 phases of voltage or asymmetrical current (VUR) - Factor of 3 phases of voltage and asymmetrical current (d0%, d2%) - USB port (optically insulated) - Integrated timer and calendar to record data Technical specifications Measurement values Measurement ranges / resolution / accuracy PCE-830 + PCE-6801 Watts AC (50 or 60Hz, PF 0.5 up to 1) 5.0 to 999.9W / 0.1W / ±1% ±0.8W 1,000 to 9,999kW / 0.001kW / ±1% ±8W 10.00 to 99.99kW / 0.01kW / ±1% ±80W 100.0 to 999.9kW / 0.1kW / ±1% ±0.8kW 1,000 to 9,999kW / 1kW / ±1% ±8kW PCE-830 + PCE-6802 Watts AC (50 or 60Hz, PF 0.5 up to 1) 5.0 to 999.9W / 0.1W / ±1% ±0.8W 1,000 to 9.999kW / 0.001kW / ±1% ±8W 10.00 to 99.99kW / 0.01kW / ±1% ±80W 100.0 to 999.9kW / 0.1kW / ±1% ±0.8kW 1,000 to 9,999kW / 1kW / ±1% ±8kW 0.000 to 9.999MW / 0.001MW / ±1% ±80kW PCE-830 + PCE-3007 Watts AC (50 or 60Hz, PF 0.5 up to 1) 10.0 to 999.9W / 0.1W / ±1% of measurement range 1,000 to 9.999kW / 0.001kW / ±1% of measurement range 10.00 to 99.99kW / 0.01kW / ±1% of measurement range 100.0 to 999.9kW / 0.1kW / ±1% of measurement range 1,000 to 9,999kW / 1kW / ±1% of measurement range PCE-830 + PCE-6801 Current AC (50 or 60Hz,
Visit the PCE Instruments UK Ltd website for more information on Three Phase Power Data Logger incl. ISO Calibration Certificate PCE-830-2